久久精品一区二区-成人免费小视频-久久精品欧美-麻豆社区-亚洲综合免费-欧美午夜精品久久久久久浪潮-有码在线播放-黄色影音-黄色片一区二区-超碰天天-日韩精选-天天干天天操天天操-亚洲在线视频免费观看-污视频网站免费在线观看-日韩欧美在线一区二区三区-国产精品美女www-欧美啪啪一区-永久黄色网址-日韩av中字-中文字幕有码av-亚洲成a人无码-成人免费视频a-黄色不打码视频-色久综合视频-国产调教av-欧美日韩在线视频免费播放-国产在线一区二-成人乱人乱一区二区三区-欧美精品黄色片-经典av在线播放

Muen
News

News

Enterprise service provider

location : Home > News > Technical information

The inverter needs to be replaced regularly within the inverter

2023-05-20 12:05:03

In the field of electrical control nowadays, the inverter is definitely the leading star in the world. Helpless as an inverter integrating electrical, electronic and other technologies, it is by no means indestructible! In order to ensure the safe and smooth operation of the inverter, in addition to regular inspection and cleaning of various internal accessories, it also needs to be replaced regularly. For this reason, I refer to various materials and combine the years of work experience to share the replacement time of the five major components inside the inverter with the majority of electricians.


 1. Cooling fan


As a prerequisite for ensuring the normal operation of the inverter, an efficient and fast direct cooling fan has become an indispensable variant of the inverter. Due to the influence of objective factors such as the wear of the internal bearing of the cooling fan and the decrease in grease performance during use, the cooling capacity of the fan is often greatly reduced. For this reason, the cooling fan should generally be replaced in 2-3 years.


2. Contactor / Relay


As a device for charging control of the inverter's internal DC circuit (mostly found in domestic inverter brands, foreign models are mostly replaced by thyristor slow charging circuits), contactors (used by high-power inverters) or relays (low-power inverters). After using for a period of time, faults such as contact ablation and virtual connection often occur. Therefore, in order to achieve the purpose of early prevention, it is often necessary to replace the contactor or relay in about 2 years.


Three, electrolytic capacitors


Electrolytic capacitors of various capacities (mostly aluminum electrolytic capacitors) that are responsible for the DC bus filtering of the inverter. With the increase of use time, electrolytic capacitors are affected by factors such as electrolyte loss, high voltage impact, and the use of ambient temperature and humidity. It needs to be replaced after 3-4 years.


Four, fuse


In the DC bus circuits of brand inverters such as Huichuan, ABB, Sanpin, etc., fuses are often used for short circuit protection. With the prolonged use time, under the influence of large current impact and temperature factors, the performance of the melt material will often deteriorate, causing the inverter to fail due to undesirable problems. For this reason, the fuse should be replaced every 7 years.


Five, PCB circuit board


This device is often overlooked by most of its peers. In fact, the PCB circuit board used in the inverter, especially the switching power supply, voltage detection and other circuit parts always need to withstand high voltage, so the electrical insulation performance of the PCB board of this part will vary with the The use time is inversely proportional, which is very unfavorable for the use of multilayer PCB circuit boards and some inverters with poor workmanship. For this part of the circuit, 7 years should be used as a replacement cycle.


Frequency converter manufacturer


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號